Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.ucsg.edu.ec/handle/3317/20925
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Bohórquez Heras, Daniel Bayardo | - |
dc.contributor.author | Macas Avecillas, Gabriel Alejandro | - |
dc.date.accessioned | 2023-05-03T17:33:04Z | - |
dc.date.available | 2023-05-03T17:33:04Z | - |
dc.date.issued | 2023-04-21 | - |
dc.identifier.uri | http://repositorio.ucsg.edu.ec/handle/3317/20925 | - |
dc.description | El presente proyecto tuvo como objetivo el estudio y análisis teórico - práctico de los transformadores monofásicos en relación a las fallas energéticas que se presentaron durante su funcionamiento, cuya importancia y comprensión de los resultados del análisis de gases disueltos (DGA) permitió conocer la evaluación de su operación, mediante mediciones eléctricas para prevenir interrupciones, debido a que las fallas comunes observadas en los transformadores eléctricos en su sistema estructural, mantenimiento y modo de operación. contribuyeron a acortar la vida útil de estos. Esta propuesta de titulación pretendió evidenciar a través del estudio teórico, la capacidad óptima de los transformadores en función del perfil de carga, las pérdidas asociadas y el costo inicial de los equipos. Sus cambios en sus regulaciones con el fin de mejorar los niveles de eficiencia de los transformadores de distribución instalados en su sistema eléctrico. También, se analizó los informes técnicos de la Corporación Nacional de Electricidad CNEL EP, a fin de conocer las pruebas que se realizaron a los transformadores que están en operación en la red eléctrica del Ecuador, y sobre la base de este análisis y de los resultados obtenidos, plantear una estrategia de operación y mantenimiento para los transformadores basadas en el cumplimiento de NORMA ASTM D 877A-02. Esta investigación también tuvo las prevenciones para evitar fallas en los transformadores eléctricos, con ejemplos, mostrando ya que estas podrían evitarse a través de una continua revisión de la condición de la salud del Transformador mediante un efectivo análisis por DGA en combinación con una efectiva evaluación de la condición | en_US |
dc.description.abstract | The objective of this project was the study and theoretical-practical analysis of single-phase transformers in relation to power failures that occurred during their operation, whose importance and understanding of the results of the dissolved gas analysis (DGA) allowed to know the evaluation of its operation, through electrical measurements to prevent interruptions, due to the common failures observed in electrical transformers in their structural system, maintenance and mode of operation. contributed to shorten the useful life of these. This degree proposal sought to demonstrate through the theoretical study, the optimal capacity of the transformers based on the load profile, the associated losses and the initial cost of the equipment. Your changes in your regulations in order to improve the efficiency levels of the distribution transformers installed in your electrical system. Also, the technical reports of the National Electricity Corporation CNEL EP were analyzed, in order to know the tests that were carried out on the transformers that are in operation in the Ecuadorian electrical network, and based on this analysis and the results obtained, propose an operation and maintenance strategy for transformers based on compliance with ASTM D 877A-02 STANDARD. This investigation also had the preventions to avoid failures in electrical transformers, with examples, showing that these could be avoided through a continuous review of the health condition of the Transformer through an effective analysis by DGA in combination with an effective evaluation of the condition. | en_US |
dc.format | application/pdf | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad Católica de Santiago de Guayaquil | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | en_US |
dc.subject | SISTEMA ELÉCTRICO | en_US |
dc.subject | DISTRIBUCIÓN DE ENERGÍA | en_US |
dc.subject | TRANSFORMADOR MONOFÁSICO | en_US |
dc.subject | MEDICIONES ELÉCTRICAS | en_US |
dc.subject | FALLAS ELÉCTRICAS | en_US |
dc.title | Estudio y análisis de fallas térmicas, dieléctricas y mecánicas en transformadores monofásicos en la empresa eléctrica CNEL Guayas-Guayaquil. | en_US |
dc.type | info:eu-repo/semantics/bachelorThesis | en_US |
Aparece en las colecciones: | Trabajos de Titulación - Carrera de Ingeniería en Eléctrico-Mecánica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
T-UCSG-PRE-TEC-IEM-317.pdf | 2,02 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons