DSpace logo
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ucsg.edu.ec/handle/3317/13352
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorUnapanta Yanchaguano, Jessy Gabriela-
dc.contributor.authorPrado López, Priscila Juana-
dc.date.accessioned2019-09-30T16:39:09Z-
dc.date.available2019-09-30T16:39:09Z-
dc.date.issued2019-09-10-
dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/13352-
dc.descriptionObjetivo: Comprobar y describir el efecto corrosivo de los irrigantes endodónticos (hipoclorito de sodio y EDTA) y ciclos de esterilización sucesivos sobre la superficie de las limas K. Materiales y métodos: Muestra 84 limas k, divididas en dos grupos, el Grupo A: 42 limas marca Dentsply MAccess y Grupo B: 42 limas marca Kendo Stainless Steel, fueron utilizadas por alumnos de pregrado durante cuatro ciclos de uso, al finalizar fueron analizadas en microscopio óptico y SEM. Resultados: Los promedios de corrosión fueron: limas #15 y #20 de ambas marcas grado 1, #25 Dentsply promedio 0.3 y Kendo 0.6, #30 Dentsply obtuvo 0 y Kendo 0.1, #35 y #40 grado 0 para ambas marcas. No hubo continuidad de la línea de corte en limas #15, #20, #25, las #30, #35 y #40 de ambas marcas conservaron la continuidad. El promedio de grado de corrosión-número de conductos se encontró en limas Dentsply que instrumentaron 3 conductos fue 0.33 y la marca Kendo fue 0.58, 4 conductos el promedio del grado de corrosión fue 0.42 para Dentsply y 0.33 para Kendo, en 5 conductos fue 0.33 para Dentsply y 0.42 para Kendo, por último las de 8 conductos obtuvieron 0.50 para ambas marcas. Discusión: Las limas K son susceptibles a la corrosión por picadura, las más afectadas son las limas #15 y #20 (para ambas marcas), lo mismo ocurre con la interrupción de la línea de corte,. Respecto a la relación entre grado de corrosión y numero de conductos instrumentados no se encontraron diferencias significativas entre las dos marcas. Conclusiones: Los irrigantes endodónticos corroen las limas K, los calibres más afectados por la corrosión, y continuidad de su línea de corte siempre fueron el #15 y #20 independiente de la marca, se debe evaluar las limas antes de su uso, en especial las de menor calibre, para corroborar que no hayan sufrido desgaste, corrosión o cualquier otro daño después del uso que pueda perjudicar el próximo tratamiento endodónticosen_US
dc.description.abstractObjective: To verify and describe the corrosive effect of endodontic irrigators (Sodium hypochlorite and EDTA) and successive sterilization cycles on the surface of K files. Materials and methods: Sample 84 K files, divided into two groups, Group A: 42 Dentsply M-Access and Group B files: 42 Kendo stainless steel files, were used by undergraduate students during four cycles of use, at the end they were analyzed by optical microscope and SEM. Results: Corrosion averages were: # 15 and # 20 files of both brands grade 1, # 25 Dentsply average 0.3 and Kendo 0.6, # 30 Dentsply obtained 0 and Kendo 0.1, # 35 and # 40 grade 0 for both brands. There was no continuity of the cutting line in files # 15, # 20, # 25, # 30, # 35 and # 40 of both brands retained continuity. The average degree of corrosion-number of conductors was found in Dentsply files that instrumented 3 conduits was 0.33 and the Kendo mark was 0.58, 4 conduits the average degree of corrosion was 0.42 for Dentsply and 0.33 for Kendo, in 5 conduits it was 0.33 for Dentsply and 0.42 for Kendo, last of the 8 behaviors they obtained 0.50 for both brands. Discussion: K files are susceptible to pitting corrosion, the most affected are files # 15 and # 20 (for both brands), the same occurs with the interruption of the cutting line. Respect the relationship between degree of corrosion and number of instrumented ducts without finding specific differences between the two brands. Conclusions: Endodontic irrigators corrode the K files, the calibers most affected by corrosion, and the continuity of their cutting line were always the # 15 and # 20 independent of the brand, the files must be evaluated before use, in especially those of smaller caliber, to corroborate that they have not suffered damage, corrosion or any other damage after use that may damage the next endodontic treatment.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectENDODONCIAen_US
dc.subjectCORROSIÓNen_US
dc.subjectIRRIGANTES ENDÓNTICOSen_US
dc.subjectMICROSCOPIO ÓPTICOen_US
dc.subjectMICROSCOPIO ELECTRÓNICO DE BARRIDOen_US
dc.titleEfecto corrosivo sobre limas K asociados a irrigantes endodónticos. Semestre B- 2018.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Odontología

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UCSG-PRE-MED-ODON-474.pdf1,05 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons