DSpace logo
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ucsg.edu.ec/handle/3317/22619
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorHidalgo Aguilar, Jaime Rafael-
dc.contributor.authorPluas Manzo, Anthony Paul-
dc.contributor.authorPluas Manzo, Cesar Antonio-
dc.date.accessioned2024-03-11T22:45:07Z-
dc.date.available2024-03-11T22:45:07Z-
dc.date.issued2024-02-19-
dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/22619-
dc.descriptionLa presente investigación tiene como objetivo principal analizar la calidad de energía mediante un medidor Sentron Pac 4200 para controlar magnitudes eléctricas y ahorro energético en Papelera Nacional S.A., el cual se basa en medir en tiempo real el consumo de energía eléctrica y la demanda de potencia para tomar medidas de ahorro y optimización de la energía eléctrica usada en el proceso en la subestación 7 de la empresa. Además, el estudio se direccionó por una metodología de enfoque mixto, es decir, cualitativo y cuantitativo, de tipo descriptivo. Las técnicas empleadas fueron la revisión bibliografía y documental interna y la observación directa. Los instrumentos requeridos se basaron en la ficha de registro de la calidad de energía y el medidor Sentron Pac 4200 que permitió obtener los datos para medirlos. Los resultados provienen de mediciones realizadas con el medidor Sentron PAC 4200 y el analizador de energía FLUKE 435 durante ocho días. Se evalúan variaciones de voltaje y de corriente, desbalance de tensión, frecuencia, armónicos y la cargabilidad del sistema. Estos indican cumplimiento con normativas como EN 50160 e IEEE519, con una cargabilidad del 82% en la subestación 7. Las conclusiones revelan que la implementación del medidor Sentron PAC 4200 ha sido fundamental para identificar y abordar áreas de ineficiencia energética, mejorando significativamente el rendimiento de equipos y procesos. Cabe mencionar que por el aporte del análisis continuo de magnitudes eléctricas se han tomado decisiones informadas que han llevado a una mayor eficiencia operativa y la reducción de pérdidas energéticas.en_US
dc.description.abstractThe main objective of this research is to analyze the quality of energy using a Sentron Pac 4200 meter to control electrical magnitudes and energy savings in Papelera Nacional S.A., which seeks to optimize energy performance, identify inefficiencies and propose solutions to improve operational efficiency and energy savings in the company's substation 7. Furthermore, the study was guided by a mixed approach methodology, that is, qualitative and quantitative, of a descriptive type. The techniques used were bibliography and internal documentary review and direct observation. The required instruments were based on the power quality recording sheet and the Sentron Pac 4200 meter that allowed obtaining the data to measure them. The results come from measurements made with the Sentron PAC 4200 meter and the FLUKE 435 energy analyzer over eight days. Voltage variations, voltage unbalance, frequency, harmonics and system chargeability are evaluated. These indicate compliance with regulations such as EN 50160 and IEEE519, with a loadability of 82% at substation 7. The conclusions reveal that the implementation of the Sentron PAC 4200 meter has been fundamental in identifying and addressing areas of energy inefficiency, significantly improving the performance of equipment and processes. It is worth mentioning that due to the contribution of the continuous analysis of electrical magnitudes, informed decisions have been made that have led to greater operational efficiency and the reduction of energy losses.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectENERGÍA ELÉCTRICAen_US
dc.subjectSUBESTACIÓN ELÉCTRICAen_US
dc.subjectPÉRDIDAS ENERGÍA ELÉCTRICAen_US
dc.subjectMAGNITUDES ELÉCTRICASen_US
dc.titleAnálisis de calidad de energía mediante un medidor Sentron Pac 4200 para controlar magnitudes eléctricas y ahorro energético en Papelera Nacional.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Ingeniería en Electricidad

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UCSG-PRE-TEC-IELE-26.pdf4,06 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons