DSpace logo
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ucsg.edu.ec/handle/3317/17091
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRamos Andrade, Kerstin Gianina-
dc.contributor.authorHerrera Sánchez, Thalía Inés-
dc.date.accessioned2021-10-08T04:25:04Z-
dc.date.available2021-10-08T04:25:04Z-
dc.date.issued2021-09-20-
dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/17091-
dc.descriptionIntroducción: El retratamiento de conductos es el procedimiento para remover materiales de obturación del conducto radicular con la finalidad de obtener buena desinfección, conformación, y obturación. El uso de sistemas rotatorios es una alternativa elegida por el operador, por su seguridad y eficacia al momento de remover la gutapercha del conducto radicular. Objetivo: Reconocer qué sistema rotatorio es eficaz removiendo gutapercha en tercios coronal, medio y apical radicular, asegurando limpieza y desinfección del conducto radicular. Materiales y métodos: Estudio de revisión bibliográfica de100 artículos, según los criterios de inclusión quedaron 42 articulos. Resultados: Todos los sistemas rotatorios dejaron mayor remanente de gutapercha en tercio apical. El sistema Profile dejo menor remanente en tercio cervical,sistema Mtwo en tercio medio y Protaper UR en tercio apical.Sistema Twisted file requirió menor tiempo para remover gutapercha del conducto radicular.La técnica de obturación de onda continua fue la que mayor dificultad presentó para ser removida la gutapercha. Conclusión: La remoción de la gutapercha es fundamental para el éxito del retratamiento. Todos los sistemas rotatorios dejaron remanente de gutapercha en el conducto radicular y mayor cantidad en el tercio apical. El sistema Hyflex NT obtuvo el menor porcentaje de remanente de gutapercha en el conducto radicular y el que menor tiempo requirió fue el sistema Twisted file, seguido de protaper retreatment que no presento mucha diferencia. Con la técnica de condensación lateral en frio se obtuvo menos remanente de gutapercha.en_US
dc.description.abstractIntroduction: Canals retreatment is the procedure to remove obturation materials from the root canal in order to obtain good disinfection, conformation, and obturation. The use of rotary systems is an alternative chosen by the operator, for its safety and effectiveness when removing gutta-percha from the root canal. Objective: To recognize which rotary system is effective by removing gutta-percha in coronal, middle and apical root thirds, ensuring cleaning and disinfection of the root canal. Materials and methods: Study of bibliographic review of 100 articles, according to the inclusion criteria, 42 articles remained. Results: All rotary systems left a greater remnant of guttapercha in the apical third. The Profile system left less remnant in the cervical third, the Mtwo system in the middle third and the Protaper UR in the apical third. The Twisted file system required less time to remove gutta-percha from the root canal. The continuous wave obturation technique was the one that presented the greatest difficulty to be gutta-percha removed. Conclusion: Removal of gutta-percha is essential for successful retreatment. All rotary systems left a remnant of gutta-percha in the root canal and a greater amount in the apical third. The Hyflex NTen_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectENDODONCIAen_US
dc.subjectGUTAPERCHAen_US
dc.subjectTÉCNICAS ROTATORIOSen_US
dc.subjectDESOBTURACIÓNen_US
dc.subjectRETRATAMIENTO ENDODÓMICOen_US
dc.titleComparación de la eficacia de limpieza de los sistemas rotatorios en la desobturación para retratamiento endodóntico : Revisión sistemática.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Odontología

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UCSG-PRE-MED-ODON-640.pdf410,67 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons