Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.ucsg.edu.ec/handle/3317/13833
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Villacrés Sánchez, Alex Raúl | - |
dc.contributor.author | Feijóo González, Eddie Rafael | - |
dc.date.accessioned | 2019-10-21T22:26:38Z | - |
dc.date.available | 2019-10-21T22:26:38Z | - |
dc.date.issued | 2019-09-13 | - |
dc.identifier.uri | http://repositorio.ucsg.edu.ec/handle/3317/13833 | - |
dc.description | El presente trabajo de titulación tiene como objetivo determinar el desempeño sísmico de edificaciones esenciales durante sismos en Ecuador a partir de 1977, enfocándose en garajes o estacionamientos para vehículos y aviones que atienden emergencias, torres de control aéreo, centro de telecomunicaciones y centro de atención de emergencias en todo el territorio ecuatoriano, ya que muchas de éstas estructuras sufrieron graves afectaciones por el cual se dará a conocer los diversos factores de vulnerabilidad que afectaron al comportamiento sísmico. La metodología consiste con la recopilación de información para identificar las edificaciones esenciales durante sismos de 1980, 1998 y 2016, por medio de periódicos e informes elaborados por diferentes profesionales, donde se determinó el tipo de suelo en el cual se asentaron las edificaciones para elaborar los espectros de diseño y espectros de respuesta. Posteriormente se obtuvo el período de vibración y derivas efectivas, para determinar el tipo de sismo de cada edificación con la finalidad de determinar el desempeño sísmico de acuerdo a la norma ecuatoriana de construcción. | en_US |
dc.description.abstract | The purpose of this work is to determine the seismic performance of essential buildings during earthquakes in Ecuador from 1977, focusing on garages or parking for vehicles and airplanes that attend emergencies, air control towers, telecommunication centers and emergencies service center throughout the Ecuadorian territory, since many of these structures suffered serious damages by different vulnerability factors that affected the seismic behavior. The methodology consists of the collection of information to identify the essential buildings during earthquakes of 1980, 1998 and 2016, through newspapers and reports prepared by different professionals where the type of soil on the buildings settled to prepare the design spectra and response spectra. Subsequently, the period of vibration and effective drifts were obtained to determine the type of earthquake of each building in order to determine the seismic performance according to the Ecuadorian construction standard. | en_US |
dc.format | application/pdf | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad Católica de Santiago de Guayaquil | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | en_US |
dc.subject | INGENIERÍA SÍSMICA | en_US |
dc.subject | DESEMPEÑO SÍSMICO | en_US |
dc.subject | ESPECTROS DE RESPUESTA | en_US |
dc.subject | PERIODO DE VIBRACIÓN | en_US |
dc.title | Desempeño de edificios esenciales durante sismos en Ecuador - caso garajes o estacionamientos para vehículos y aviones que atienden emergencias, torres de control aéreo, Centros de Telecomunicaciones y centros de atención de emergencias. | en_US |
dc.type | info:eu-repo/semantics/bachelorThesis | en_US |
Aparece en las colecciones: | Trabajos de Titulación - Carrera de Ingeniería Civil |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
T-UCSG-PRE-ING-IC-310.pdf | 5,35 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons